REAM HMI For Coiled Tubing

Real-time Electronic Acquisition & Monitoring with Human Machine Interface

REAM HMI for COILED TUBING

The REAM HMI is a user-friendly data acquisition system that reads data from electronic sensors and displays the data on a TFT touch screen, which acts as both an input and an output device. The system records the data on solid-state Compact Flash memory and allows remote monitoring of the data. Two screen size options are available, 7” and 9”.

The system is made of two main parts, REAM is a microprocessor-based data acquisition board, which collects data from electronic sensors, digitizes the readings, and supplies the appropriate excitation voltage to the sensors. The HMI communicates with the REAM board to retrieve, display, and store the data.

REAM has analogue, counters (frequency), and quadrature channels. The analogue channels accept signals from sensors with 0-5 vdc, 0-10 vdc, or 4-20 mA output. The counters accept pulse signals produced by proximity switches or magnetic pickups. The quadrature channel accepts an up/down counter, such as a depth encoder.

In addition to the REAM board, the HMI can communicate with many other devices such as Medco’s Tubing Ovality Monitor (TOM), NuFlo MC-III Flow Analyser, and control devices such as Medco’s Emergency Injector Stop System (EISS).

The outputs are available on Web Pages, they can be viewed remotely on a Local Area Network (LAN) or even a Wide Area Network (WAN), provided that proper Internet connections are available. There are many other features in the HMI and these can be tailored to the client’s request.

REAM HMI COILED TUBING Specs

Power

12 vdc, max. of 1.5 Amps. Supplied with AC/DC converter 95 to 260 VAC

Temperature

0 to 50'C

Parameters

Depth, Tubing Speed, Weight, Circulation Pressure, Wellhead Pressure, Casing Pressure, Flow Rate, N2 Rate, Fluid Total, N2 Total.

Portable Configuration (FLIGHT CASE II)

Power requirement: 10-36 vdc, max. of 36 Watts. Supplied with AC/DC converter 95 to 260 VAC.
Operating temperature: -20 to 70 deg C (except HMI).
Available Parameters: Depth, Tubing Speed, Weight, Circulation Pressure, Wellhead Pressure, Casing Pressure, Flow Rate, N2 Rate,
Fluid Total, N2 Total.
Analogue In channels: Standard 8 (16bit) 4-20 mA/0-10v. Expandable to any multiples of 8.
Frequency In channels: Standard 6 (4 of which could be Quadrature). Expandable to any multiples of 6.
Analogue Output: Optional. Any number of Analogue (16 bit/4-20mA) via added loop splitters.
Digital Output: Optional. Binary (on/off) relay.
HMI 9” colour touch screen Human Machine Interface. Temperature rating 0 to 50 deg C
(also available in 7” and 10” HMI)
Dimensions: 430x290x155mm
Weight:8 Kgs

Fixed Configuration (Stainless Steel enclosure)

Power requirement: 10-36 vdc, max. of 36 Watts. Supplied with AC/DC converter 95 to 260 VAC.
Operating temperature: -20 to 70 deg C (except HMI).
Available Parameters: Depth, Tubing Speed, Weight, Circulation Pressure, Wellhead Pressure, Casing Pressure, Flow Rate, N2 Rate,
Fluid Total, N2 Total.
Analogue In channels: Standard 8 (16bit) 4-20 mA/0-10v. Expandable to any multiples of 8.
Frequency In channels: Standard 6 (4 of which could be Quadrature). Expandable to any multiples of 6.
Analogue Output: Optional. Any number of Analogue (16 bit/4-20mA) via added loop splitters.
Digital Output: Optional. Binary (on/off) relay.
HMI Recommended 9” colour touch screen Human Machine Interface. Temperature 0 to 50 deg C (also available in in 7” up to 15” and in separate enclosure)
Dimensions: 300mm (H) x 200mm (W) x 150mm (D) 1.2mm gauge brushed 316 stainless steel
2mm zintec mounting plate

Download our complete Data Sheet Here